Analysis Initialization
Parthenon applications can load a previously written HDF5 or openPMD output and run application-native diagnostics without advancing the simulation. This analysis mode reuses the application’s packages, mesh data structures, boundary communication, and output system, but it is distinct from a normal restart.
Analysis mode is useful when a diagnostic is easier to express with the application’s existing C++ kernels than with an external postprocessing tool. Typical examples include computing derived fields, histograms, reductions, or converted output formats after a simulation has completed.
Running an analysis
Invoke an application with both an analysis source and a separate analysis input file:
./my-application -a /path/to/source.phdf -i parthinput.analysis
The -a and -r options are mutually exclusive. Unlike -r, -a requires an
input file because the analysis input defines the diagnostics and outputs to perform.
The supported source formats depend on the configured I/O backends:
.phdfand.rhdffiles require HDF5 support..bpopenPMD series require openPMD and ADIOS2 support. A trailing slash on the series directory is accepted.
An unsupported suffix, or a source whose backend was disabled at build time, produces a startup error.
Analysis and restart differ in several important ways:
Analysis does not set
Globals::is_restart. Applications can useParthenonManager::IsAnalysis()when they need to distinguish analysis from both a fresh run and a restart.The source mesh hierarchy and selected field data are loaded, but problem generators are not called.
The evolution loop and timestep initialization are skipped, so the analysis run does not advance the source cycle or time.
Boundary communication is performed after the selected fields are loaded.
UserWorkBeforeLoopruns once, followed by the output pass. Output callbacks run if at least one output is selected.
Selecting source fields
The optional fields entry in <parthenon/analysis> limits which mesh fields are
loaded:
<parthenon/analysis>
fields = density, pressure, tracers_7
Names are logical Parthenon field labels, including the sparse ID suffix for an individual sparse field. They are not HDF5 dataset paths or openPMD mesh-record names.
If fields is omitted or empty, Parthenon requests every field discoverable in the
source. If it is supplied, Parthenon loads the intersection of the requested names and
the source catalog. Unknown names are ignored. A field must also be registered by the
application’s packages before it can be included in the resolved analysis state.
Current HDF5 and openPMD outputs store an OutputDatasetNames catalog containing the
logical labels. Legacy HDF5 files fall back to compatible root-dataset discovery.
OpenPMD format-version-2 files can recover labels from mesh-record names. Format-version-1
openPMD files do not contain an unambiguous catalog, so fields must be supplied
explicitly for those files.
Analysis-only fields and swarms
Packages can register data needed only while postprocessing by adding
Metadata::Analysis. The flag is supported for dense fields, sparse fields, and
swarms. Such data is included in the resolved analysis state even when it is absent from
the source file.
For example:
Metadata diagnostic({Metadata::Cell, Metadata::Derived, Metadata::OneCopy,
Metadata::Analysis});
package->AddField("diagnostic", diagnostic);
Metadata sparse_diagnostic({Metadata::Cell, Metadata::Derived, Metadata::OneCopy,
Metadata::Sparse, Metadata::Analysis});
package->AddSparsePool("diagnostic_pool", sparse_diagnostic,
std::vector<int>{7});
Metadata::Analysis controls state construction; it does not initialize values.
Applications must populate analysis-only data in a callback that runs during analysis.
UserWorkBeforeOutput is usually the appropriate location because it executes after
the source data has been loaded and communicated and immediately before output is
written. Applications must allocate analysis-only sparse fields before writing them.
File-backed fields are converted into restart-loaded derived fields for analysis. Their shape, component labels, and applicable refinement operations are retained, while independent ownership and flux relationships are removed. They participate in the boundary communication required to make the loaded data usable by diagnostics.
Input precedence and source time
Analysis parameters are assembled in this order, with each later source overriding earlier values:
The input embedded in the source dump (or restart) file.
The source iteration’s actual
start_time,dt, andncyclemetadata.The required analysis input supplied with
-i.Command-line assignments.
This allows an analysis to inherit the source mesh and package configuration while changing boundaries, diagnostic settings, output definitions, or time parameters. For example:
./my-application -a source.out0.final.phdf -i parthinput.analysis \
parthenon/time/ncycle=100 Advection/cfl=0.5
The source mesh geometry must remain compatible with the stored hierarchy. Boundary conditions may be overridden by the analysis input and are applied when the loaded data is communicated.
Selecting analysis outputs
Set analysis_output = true on output blocks that must be triggered by the analysis
signal:
<parthenon/job>
problem_id = analysis
<parthenon/analysis>
fields = density, pressure
<parthenon/output0>
file_type = hdf5
dt = 1.0
analysis_output = true
variables = density, pressure, diagnostic
The output block must still be enabled with a nonnegative dt or dn. The
analysis_output setting forces the block to run for the analysis signal regardless
of whether its normal cadence is due. Other enabled output blocks continue to obey their
ordinary scheduling conditions, so use negative dt and dn values to disable
blocks that should never run during this invocation.
Analysis output uses the normal numbered-output path rather than the final label.
The initial number can reflect counters stored in the source file. No additional final
output is written after the analysis pass.
UserWorkBeforeOutput is called before the first selected non-history output, so it
can compute analysis-only fields and diagnostics. Analysis can read one supported
backend and write another; for example, an openPMD source can produce HDF5 diagnostics
when both backends are enabled.
Warning
An output written during analysis contains only the resolved analysis state. Parthenon marks this state in the embedded input and rejects using the resulting file as a normal restart source.
Complete example
The advection example includes an analysis input that loads two fields, computes any
application diagnostics in UserWorkBeforeOutput, and writes one HDF5 analysis
output:
# This file was made in part with generative AI.
# ========================================================================================
# Parthenon performance portable AMR framework
# Copyright(C) 2026 The Parthenon collaboration
# Licensed under the 3-clause BSD License, see LICENSE file for details
# ========================================================================================
<parthenon/job>
problem_id = analysis
<parthenon/analysis>
fields = advected, my_derived_var
<Advection>
fill_derived = false
<parthenon/output0>
file_type = hdf5
dt = 1.0
analysis_output = true
variables = advected, my_derived_var
Run it against an existing output:
./advection-example -a advection.out0.00010.phdf \
-i ../../example/advection/parthinput.analysis
Change file_type to openpmd to write an openPMD result when that backend is
enabled. The source and destination backends do not need to match.
The regression fixtures in tst/regression/test_suites/analysis_data and
tst/regression/test_suites/restart_opmd provide maintained HDF5 and openPMD examples.
Troubleshooting
- No analysis output is produced
Confirm that the output block has a nonnegative
dtordnandanalysis_output = true.- A requested field is missing
Confirm that the logical label is present in the source and registered by the application’s packages. For legacy openPMD format-version-1 files, list every desired field explicitly.
- Ghost values are not suitable for the diagnostic
Ensure the field metadata supports the required refinement and boundary operations, and request ghost zones in the output if they must be inspected afterward.
- An analysis output cannot be restarted